DateMethod of FlowFlow - Field!!(gal/min)pH - Field!!(S.U.)pH - Lab!!(S.U.)ORP - Field!!(mvolts)DO - Field!!(mg/L)Temp - Field!!(C)Cond - Lab!!(umhos/cm)Alkalinity - Field!!(mg/L)Alkalinity - Lab!!(mg/L)Acidity - Lab!!(mg/L)T. Fe  - Lab!!(mg/L)D. Fe - Lab!!(mg/L)T. Mn  - Lab!!(mg/L)D. Mn  - Lab!!(mg/L)T. Al - Lab!!(mg/L)D. Al - Lab!!(mg/L)SO4 - Lab!!(mg/L)TSS - Lab!!(mg/L)
2009-09-14--0----------------------------------
2010-04-20--2506.26.34122.00.110.644047.0030.19-7.6418.35--0.80--0.04--163.110
2012-05-08------5.86------381--26.23117.5--0.9--0--142.313
2018-05-09--3006.695.78--0.2711.24064029.22-6.1712.69--0.67--0--144.96
Minimum: 06.25.78122.00.110.63814026.23-7.6412.69--0.67--0--142.36
Maximum: 3006.696.34122.00.2711.244047.0030.19118.35--0.9--0.04--163.113
Average: 183.3----1220.1910.940943.528.55-4.2716.18--0.79--0.01--150.19.7
Range: 3000.490.5600.170.65973.968.645.66--0.23--0.04--20.87
Median: 2506.455.86122.00.1910.940643.529.22-6.1717.5--0.80--0--144.910
Loading (lb/day): 142.597.88-22.5750.37--2.41--0.06--

Sample Point Description: Abandoned Mine Discharge; SR115 emanates from a deep mine. Typically only flows during high flow periods
1. Records with no value are not included in statistical calculations.
2. Values lower than the minimum detection limit are assumed to be 0.
3. Average pH is not calculated as a mean of pH values, but rather a mean of hydronium ion concentration.
4. Dissolved metals used for calculated acidity values when available. Acidities calculated from total metals may be exaggerated.
5. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.
  To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or
  send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.



Argentine Central SR115 Water Quality Report - SR115WL
DateMethod of FlowFlow - Field!!(gal/min)pH - Field!!(S.U.)pH - Lab!!(S.U.)ORP - Field!!(mvolts)DO - Field!!(mg/L)Temp - Field!!(C)Cond - Lab!!(umhos/cm)Alkalinity - Field!!(mg/L)Alkalinity - Lab!!(mg/L)Acidity - Lab!!(mg/L)T. Fe  - Lab!!(mg/L)D. Fe - Lab!!(mg/L)T. Mn  - Lab!!(mg/L)D. Mn  - Lab!!(mg/L)T. Al - Lab!!(mg/L)D. Al - Lab!!(mg/L)SO4 - Lab!!(mg/L)TSS - Lab!!(mg/L)
2009-09-14--0----------------------------------
2010-04-20--2506.76.66106.09.215.041039.019.76-9.6012.90--0.77--0--165.316
2012-05-08------6.14------365--25.83-3.389.6--0.86--0--140.38
2018-05-09--3006.86.07--9.5917.13874520.3-4.989.76--0.67--0--142.410
Minimum: 06.76.07106.09.215.036539.019.76-9.609.6--0.67------140.38
Maximum: 3006.86.66106.09.5917.14104525.83-3.3812.90--0.86------165.316
Average: 183.3----1069.416.13874221.96-5.9910.75--0.77------149.311.3
Range: 3000.10.5900.392.14566.076.223.3--0.19------258
Median: 2506.756.14106.09.416.13874220.3-4.989.76--0.77------142.410
Loading (lb/day): 139.566.18-23.3636.92--2.36------

Sample Point Description: Final Effluent of SR115 passive system. Sampled at wetland spillway.
1. Records with no value are not included in statistical calculations.
2. Values lower than the minimum detection limit are assumed to be 0.
3. Average pH is not calculated as a mean of pH values, but rather a mean of hydronium ion concentration.
4. Dissolved metals used for calculated acidity values when available. Acidities calculated from total metals may be exaggerated.
5. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.
  To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or
  send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.