Standard Water Quality Report
Download Raw Water Quality Data CSVSample Point - DPWS |
Sample Point Description: AMD; Influent to Green Garden Run; SIS Database says this is Dudley Public Water Supply spring - Source for Green Garden Road system???
- Records with no value are not included in statistical calculations.
- Values lower than the minimum detection limit are assumed to be 0.
- Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
- This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.
To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.
Sample Point - GGR1 |
Date | Method of Flow | Flow - Field (gal/min) | pH - Field (S.U.) | pH - Lab (S.U.) | ORP - Field (mvolts) | DO - Field (mg/L) | Temp - Field (C) | Cond - Lab (umhos/cm) | Alkalinity - Field (mg/L) | Alkalinity - Lab (mg/L) | Acidity - Lab (mg/L) | T. Fe - Lab (mg/L) | D. Fe - Lab (mg/L) | T. Mn - Lab (mg/L) | D. Mn - Lab (mg/L) | T. Al - Lab (mg/L) | D. Al - Lab (mg/L) | SO4 - Lab (mg/L) | TSS - Lab (mg/L) | Ferrous Iron (mg/L) Lab |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2019-05-07 | -- | 130.000 | 6.00 | 6.4 | -- | -- | 32.00 | 271 | -- | 30 | -9 | <0.05 | -- | 0.09 | -- | 0.36 | -- | 93 | 4 | -- |
2020-06-02 | measured | 60 | 6 | 6.5 | -- | -- | 4 | 291 | -- | 24 | -8 | 0.11 | -- | 0.11 | -- | 0.43 | -- | 107 | 5 | -- |
Minimum: | 0 | 60 | 6.00 | 6.4 | -- | -- | 4 | 271 | -- | 24 | -9 | 0.11 | -- | 0.09 | -- | 0.36 | -- | 93 | 4 | -- |
Maximum: | 0 | 130.000 | 6.00 | 6.5 | -- | -- | 32.00 | 291 | -- | 30 | -8 | 0.11 | -- | 0.11 | -- | 0.43 | -- | 107 | 5 | -- |
Average: | 0 | 95 | 6.00 | 6.45 | -- | -- | 18.0 | 281 | -- | 27 | -8.5 | 0.11 | -- | 0.10 | -- | 0.40 | -- | 100.0 | 4.5 | -- |
Range: | 0 | 70 | 0 | 0.1 | -- | -- | 28 | 20 | -- | 6 | 1 | 0 | -- | 0.02 | -- | 0.07 | -- | 14 | 1 | -- |
Median: | 0 | 95 | 6 | 6.45 | -- | -- | 18 | 281 | -- | 27 | -8.5 | 0.11 | -- | 0.1 | -- | 0.4 | -- | 100 | 4.5 | -- |
Loading (lb/day): | -- | 32.09 | -9.92 | 0.08 | -- | 0.11 | -- | 0.44 | -- |
Sample Point Description: Green Garden Road Pond #1; ****NOT CURRENTLY IN SIS - WILL NEED TO GO BACK TO IT****
- Records with no value are not included in statistical calculations.
- Values lower than the minimum detection limit are assumed to be 0.
- Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
- This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.
To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.
Sample Point - GGR2 |
Date | Method of Flow | Flow - Field (gal/min) | pH - Field (S.U.) | pH - Lab (S.U.) | ORP - Field (mvolts) | DO - Field (mg/L) | Temp - Field (C) | Cond - Lab (umhos/cm) | Alkalinity - Field (mg/L) | Alkalinity - Lab (mg/L) | Acidity - Lab (mg/L) | T. Fe - Lab (mg/L) | D. Fe - Lab (mg/L) | T. Mn - Lab (mg/L) | D. Mn - Lab (mg/L) | T. Al - Lab (mg/L) | D. Al - Lab (mg/L) | SO4 - Lab (mg/L) | TSS - Lab (mg/L) | Ferrous Iron (mg/L) Lab |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2019-05-07 | -- | 3.100 | 7.00 | 7.0 | -- | -- | 14.00 | 310 | -- | 69 | -50 | 0.09 | -- | 0.08 | -- | 0.20 | -- | 77 | 7 | -- |
2020-06-02 | measured | 2 | 7 | 6.8 | -- | -- | 26 | 320 | -- | 59 | -40 | 6.84 | -- | 1.88 | -- | 5.85 | -- | 86 | 290 | -- |
Minimum: | 0 | 2 | 7.00 | 6.8 | -- | -- | 14.00 | 310 | -- | 59 | -50 | 0.09 | -- | 0.08 | -- | 0.20 | -- | 77 | 7 | -- |
Maximum: | 0 | 3.100 | 7.00 | 7.0 | -- | -- | 26 | 320 | -- | 69 | -40 | 6.84 | -- | 1.88 | -- | 5.85 | -- | 86 | 290 | -- |
Average: | 0 | 3 | 7.00 | 6.90 | -- | -- | 20.0 | 315 | -- | 64 | -45.0 | 3.47 | -- | 0.98 | -- | 3.03 | -- | 81.5 | 148.5 | -- |
Range: | 0 | 1.1 | 0 | 0.2 | -- | -- | 12 | 10 | -- | 10 | 10 | 6.75 | -- | 1.8 | -- | 5.65 | -- | 9 | 283 | -- |
Median: | 0 | 2.55 | 7 | 6.9 | -- | -- | 20 | 315 | -- | 64 | -45 | 3.47 | -- | 0.98 | -- | 3.03 | -- | 81.5 | 148.5 | -- |
Loading (lb/day): | -- | 1.99 | -1.86 | 0.08 | -- | 0.02 | -- | 0.07 | -- |
Sample Point Description: Green Garden Road Pond #2; Final Effluent of system? ****NOT CURRENTLY IN SIS - WILL NEED TO GO BACK TO IT****
- Records with no value are not included in statistical calculations.
- Values lower than the minimum detection limit are assumed to be 0.
- Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
- This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.
To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.