Brewster Hollow SX8-D1

  1. id /
  2. uuid /
  3. langcode /
  4. type /
  5. uid /
  6. label /
  7. created /
  8. changed /
  9. path /
  10. default_langcode /
  11. feeds_item /
  12. field_address_secondary /
  13. field_amd_source /
  14. field_amlis_id /
  15. field_city /
  16. field_construction_year /
  17. field_contact_city /
  18. field_contact_email /
  19. field_contact_organization /
  20. field_contact_org_entity /
  21. field_contact_person /
  22. field_contact_postal_code /
  23. field_contact_state /
  24. field_contact_user /
  25. field_contact_website /
  26. field_country /
  27. field_county /
  28. field_description /
  29. field_description_new /
  30. field_effluent_acidity /
  31. field_effluent_alkalinity /
  32. field_effluent_ferrous_iron /
  33. field_effluent_flow /
  34. field_effluent_ph /
  35. field_effluent_sulfate /
  36. field_effluent_total_aluminum /
  37. field_effluent_total_iron /
  38. field_effluent_total_manganese /
  39. field_elevation /
  40. field_extended_description /
  41. field_gallery /
  42. field_gps /
  43. field_influent_acidity /
  44. field_influent_ferrous_iron /
  45. field_influent_flow_average /
  46. field_influent_ph /
  47. field_influent_sulfate /
  48. field_influent_total_aluminum /
  49. field_influent_total_iron /
  50. field_influent_total_manganese /
  51. field_latitude /
  52. field_links /
  53. field_location /
  54. field_longitude /
  55. field_osm_id /
  56. field_pd_organization_entity /
  57. field_performance_acidity /
  58. field_performance_alkalinity /
  59. field_performance_aluminum /
  60. field_performance_iron /
  61. field_performance_manganese /
  62. field_performance_treated /
  63. field_phone_number /
  64. field_postal_code /
  65. field_primary_image /
  66. field_project_designer /
  67. field_project_designer_organizat /
  68. field_project_status /
  69. field_project_type /
  70. field_quad /
  71. field_report_cache /
  72. field_report_full_cache /
  73. field_report_summary_cache /
  74. field_responsible_organization /
  75. field_responsible_org_entity /
  76. field_river_basin /
  77. field_spotlight /
  78. field_state /
  79. field_stream /
  80. field_street /
  81. field_total_capital_cost /
  82. field_township /
  83. field_website /

Brewster Hollow SX8-D1

Project Details
Construction Year
2014
Total Cost
$0.00
Total Capital Cost
0.00
Latitude
40.162139
Longitude
-78.227483
Elevation
Project
Brewster Hollow SX8-D1
GPS
0
AMD Source
Underground
Project Type
Passive Treatment System
River Basin
Susquehanna
Watershed
Quad
City
County
Bedford
State
Stream
Brewster Hollow

Description: The SX8-D1 AMD source, which discharges from an old, buried, underground mine entry along the north bank of Brewster Hollow in the village of Defiance, had severe impacts and at times was the only source of water in the downstream segment of the stream. The final treatment system design involved installation of a mine seal that forced the water from the buried mine tunnel up into the system and uses a large flushable limestone bed (FLB) based passive treatment system.

Water Quality Data Summary

Treatment Technologies
Treatment Technology Quantity
Aerobic Wetland 1
Flushable Limestone Bed 1
Settling Pond 1
Brewster Hollow SX8-D1
Location Links
Map
GPS Directions
Project Contacts
Contact Person: btwatershed
Contact Organization: Broad Top Township
Project Designer:
Project Designer Organization:
Project Responsible Organization: Broad Top Township
Funding
no data available
Organizations
no data available
External System IDs
no data available
Project Performance