Skip navigation
Project Details
  • Aluminaide
    No
    Underground
    Passive Treatment System
    Huling Run
    East Brady
    UNT to Huling Run

    A passive system was installed on PA State Gamelands 105 to treat AMD from an abandoned deep mine discharge that was impacting an unnamed tributary to Huling Run

    2018
    $215,148.46
    $151,655.00
Water Quality Data Summary
Sample PointFlow - Field!!(gal/min)pH - Field!!(S.U.)pH - Lab!!(S.U.)ORP - Field!!(mvolts)DO - Field!!(mg/L)Temp - Field!!(C)Cond - Lab!!(umhos/cm)Alkalinity - Field!!(mg/L)Alkalinity - Lab!!(mg/L)Acidity - Lab!!(mg/L)T. Fe  - Lab!!(mg/L)D. Fe - Lab!!(mg/L)T. Mn  - Lab!!(mg/L)D. Mn  - Lab!!(mg/L)T. Al - Lab!!(mg/L)D. Al - Lab!!(mg/L)SO4 - Lab!!(mg/L)TSS - Lab!!(mg/L)
In15--3.1----------088.41.46--1.56--5.49--109.20
Out15.4--7.71----------127.5-110.570.48--0.85--0--103.88
Treatment Technologies
Treatment Technology Quantity of Elements
Auto-Flushing (Solar) Limestone Pond 1