Water Quality Report


EXPORT RAW DATA TO CSV

Cold Stream Shotgun Seep Water Quality Report - PA256A

Export Sample Point Report  /  Inflow: Yes / Outflow: No
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (Mg/L) Lab
2010-03-24--202.022.7----7.519700039118.3--8.72--39.4--763<5--
2012-05-17--43.22.6----1119100034212.64--8.04--32.26--7397--
2018-05-08----2.792.7----11.801880--032512.19--7.01--26.38--6823--
Minimum:--42.022.6----7.518800032512.19--7.01--26.38--6823--
Maximum:--203.22.7----11.8019700039118.3--8.72--39.4--7637--
Average:--122.672.67----10.11,92000352.6714.38--7.92--32.68--728.05.0--
Range:--161.180.1----4.39000666.11--1.71--13.02--814--
Median:--122.792.7----1119100034212.64--8.04--32.26--7395--
Loading (lb/day):0055.222.5--1.24--5.51--

Sample Point Description: Abandoned Mine Discharge; comes off road into passive system

  1. Records with no value are not included in statistical calculations.
  2. Values lower than the minimum detection limit are assumed to be 0.
  3. Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
  4. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.

To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.


Cold Stream Shotgun Seep Water Quality Report - PA256B

Export Sample Point Report  /  Inflow: No / Outflow: No
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (Mg/L) Lab
2010-03-24--204.626.2----8.313404566-301.25--5.84--5.39--67420--
2012-05-17--45.96.5----151500140120-7128.04--11.59--0.06--74717--
Minimum:--44.626.2----8.313404566-711.25--5.84--0.06--67417--
Maximum:--205.96.5----151500140120-3028.04--11.59--5.39--74720--
Average:--125.266.35----11.71,42092.5093-50.5014.65--8.72--2.73--710.518.5--
Range:--161.280.3----6.716095544126.79--5.75--5.33--733--
Median:--125.266.35----11.65142092.593-50.514.65--8.72--2.73--710.518.5--
Loading (lb/day):8.7710.82-5.310.82--0.98--0.65--

Sample Point Description: Effluent of Sulfate Reducing Bioreactor

  1. Records with no value are not included in statistical calculations.
  2. Values lower than the minimum detection limit are assumed to be 0.
  3. Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
  4. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.

To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.


Cold Stream Shotgun Seep Water Quality Report - PA256C

Export Sample Point Report  /  Inflow: No / Outflow: Yes
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (Mg/L) Lab
2009-10-23----5.256.2----12.0214202023100.26--0.69--0.06--8158--
2010-03-24--205.045.6----10.412603016633.29--7.22--11.5--65121--
2012-05-17--45.15.1----20135059211.62--10.31--1.46--7670--
2018-05-08----2.792.8----16.381610--02819.62--7.54--24.58--6107--
Minimum:--42.792.8----10.4126050100.26--0.69--0.06--6100--
Maximum:--205.256.2----20161030232819.62--10.31--24.58--81521--
Average:--124.554.93----14.71,41018.331293.753.70--6.44--9.40--710.89.0--
Range:--162.463.4----9.635025232719.36--9.62--24.52--20521--
Median:--125.075.35----14.213852012.5422.46--7.38--6.48--7097.5--
Loading (lb/day):3.732.148.080.43--1.12--1.42--

Sample Point Description: Effluent of Settling Pond and Final effluent of Shotgun passive system.

  1. Records with no value are not included in statistical calculations.
  2. Values lower than the minimum detection limit are assumed to be 0.
  3. Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
  4. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.

To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.


Cold Stream Shotgun Seep Water Quality Report - PA256D

Export Sample Point Report  /  Inflow: No / Outflow: No
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (Mg/L) Lab
2009-10-23----2.573.2----10.418000034926.4--13.5--43--10669--
2018-05-08----2.862.9----11.511540--029510.82--6.81--26.68--6302--
Minimum:----2.572.9----10.415400029510.82--6.81--26.68--6302--
Maximum:----2.863.2----11.5118000034926.4--13.5--43--10669--
Average:----2.723.05----11.01,67000322.0018.61--10.16--34.84--848.05.5--
Range:----0.290.3----1.11260005415.58--6.69--16.32--4367--
Median:----2.723.05----10.9616700032218.61--10.16--34.84--8485.5--
Loading (lb/day):------------------

Sample Point Description: Abandoned Mine Discharge flowing in a diversion ditch which is carried to a PennDOT mitigation wetland

  1. Records with no value are not included in statistical calculations.